Changing from 12V to 24V Trolling Motor wires. I’ve a vessel I recently bought that had manufacturing plant 12V 8 gauge wiring and connect up front

Changing from 12V to 24V Trolling Motor wires. I’ve a vessel I recently bought that had manufacturing plant 12V 8 gauge wiring and connect up front

  • Jul 8, 2015
  • # 1
  • chevync20

    Twelve Pointer

    I have a watercraft not long ago i purchased that had manufacturing plant 12V 8 determine wiring and connect in advance. My question for you is, I want to run a Minn Kota Powerdrive V2 70 pound 24V motor, but need to revise anything to 24. I’m sure simple tips to cable batteries in match and show, but need to find out what I need certainly to exchange. By wiring right up in show to 24V, was two wire enough on the connect? Does a 24V trolling engine has 4 cables? You will find owned 12V motors in earlier times, but never any 24V setups. Whoever can point me personally within the correct course, I would considerably relish it.

    The 70 LB 24V brings a max of 42 amps, therefore I sensed the 8 gauge wires could well be enough. Any simple to follow hyperlinks could well be appreciated. We read some with only two wires and some with three and four. Just want to verify I get every thing ordered and prepared for whenever the motor shows up. Thank you once again

    • Jul 8, 2015
  • number 2
  • Eric Revo

    Old Mossy Horns
    • Jul 8, 2015
  • # 3
  • Dan in NC

    Six Pointer
    • Jul 8, 2015
  • no. 4
  • catfishrus

    Twelve Tip
    • Jul 8, 2015
  • #5
  • chevync20

    Twelve Pointer
    • Jul 8, 2015
  • # 6
  • Eric Revo

    Old Mossy Horns
    • Jul 8, 2015
  • # 7
  • sky hawk

    Old Mossy Horns

    As stated, 24v will pulling considerably amps than 12v. Anytime the wires got enough for 12v, it is enough for any 24v.

    The only exception getting if you go the place on the batteries and increase the length. Length makes a difference. Otherwise, and you’re simply exchanging completely, you should not make the effort modifying the wires.

    • Jul 8, 2015
  • #8
  • chevync20

    Twelve Tip
    • Jul 8, 2015
  • no. 9
  • Mr.Gadget

    Past Mossy Horns
    • Jul 8, 2015
  • #10
  • Mr.Gadget

    Old Mossy Horns

    As mentioned, 24v will take considerably amps than 12v. So if the wiring had been sufficient for 12v, it’ll be adequate for all the 24v.

    The actual only real exclusion are should you decide push the situation of the battery packs while increasing the exact distance. Range is important. If not, and you are clearly merely changing completely, do not bother switching the wiring.

    • Jul 8, 2015
  • #11
  • chevync20

    Twelve Pointer
    • Jul 8, 2015
  • #12
  • Mr.Gadget

    Past Mossy Horns

    Yep contemplate it like drinking water movement. if you would like a 2″ water line but simply have 1″ you are able to two lines to have the conclusion require.

    Same way with power. You can operate 2 lines both operated 24v but visiting the same connect you are able to operate twice as much amps as only working one-line https://besthookupwebsites.org/farmersonly-review/ state range x runs 50 amps but 2 contours x/2 work 25 amps each providing the 50 amps.

    • Jul 8, 2015
  • #13
  • chevync20

    Twelve Tip
    • Jul 9, 2015
  • #14
  • air hawk

    Old Mossy Horns

    24V draws considerably existing than 12V. Therefore if it actually was suitable for 12, it really is ample for 24. You did get that part correct?

    There are plenty of various gauges of wire that function. The larger the cable the reduced voltage fall you should have. Presuming a 20′ wire (40′ circuit), 42 amp, 24V. 8 AWG needs to be fine. I wouldn’t normally run heavier cable for a motor that’s going to extract less present than the factory supposed.

    Here’s Minn Kota’s Conductor determine information: (click the suitable back link)

    Observe that the 12V 55lb. push unit directly above yours pulls much more amps and requires larger gauge cable. In addition spot the ideal circuit breaker is obviously more than the maximum amp draw from the motor. That is because you don’t want it to visit each time you turn your engine on higher. Do not set a 40 amp breaker on a 42 amp motor. Remember that 95per cent of that time period you may not bring anywhere near 42 amps.